SmartSolo 3C Seismic Node Comparison

Compare five SmartSolo 3C configurations by sensor specification, weight, storage, endurance and access mode, with links to the English source documents and their test conditions.

SmartSolo Scientific · Updated

These are representative specifications from the cited editions. Confirm the current ordered configuration, accessories and endurance for the actual project; optional storage is not necessarily fitted as standard.

Compare the requirements

On a narrow screen, scroll the table horizontally to see every column.

SmartSolo 3C Seismic Node Comparison — selection reference
Model / sourceFrequency specificationWeight¹StoragePublished continuous endurance²
IGU-16HR 3C 5Hz5 Hz natural frequency2.4 kg64 GB30 days at 2 ms, 25 °C
IGU-16HR 3C 2Hz2 Hz natural frequency5.4 kg64 GB; expandable to 128 GB40 days at 2 ms, 25 °C
IGU-16HR 3C AIO 5Hz5 Hz natural frequency2.8 kg64 GB; expandable to 128 GB40 days at 2 ms, 25 °C
IGU-BD3C-55 s–150 Hz bandwidth2.8 kg64 GB; expandable to 128 GB30 days at 2 ms, 25 °C
IGU-16HR 3C 2Hz ETH2 Hz natural frequency5.8 kg64 GB; expandable to 128 GB40 days offline at 2 ms, 25 °C; 7 days with continuous Ethernet transmission

¹ The cited sheets include the battery and spike for the four non-ETH models; the ETH sheet includes the battery and leveling nuts. Accessories and installed configurations may change transport weight.

² Continuous means 24 hours per day. The ETH sheet lists 7 days for continuous Ethernet transmission separately from offline endurance. Confirm transmission settings and operating conditions for the proposed network.

Shortlist by the measurement requirement

Start with components and the frequency-response requirement. Compare the 2 Hz and 5 Hz geophone models using response and noise data. Include the BD3C-5 when its stated 5 s–150 Hz range matches the experiment. A single frequency number cannot rank these instruments.

Then choose the service workflow

AIO, 2 Hz and BD3C sheets list local Bluetooth QC and USB 3.0 download. The ETH variant lists Ethernet waveform/status access and USB 2.0 download. Select the interface your field team can support, and confirm software, connectors and network infrastructure before procurement.

Request a configuration-specific quotation

Provide the selected model, component count, fitted storage, accessories, temperature range, recording interval and duration. For an Ethernet project, include the power supply, cable distances, backhaul and acceptable data delay. Request current English specifications with the quotation.

English specifications used here

Figures refer to these document editions. Confirm the latest specification and the exact configuration with your quotation.

Explore the instruments

Plan the application

Documented field examples

These accounts describe their cited projects. They do not prescribe a configuration for a different site.

Continue your comparison