SmartSolo 3C Seismic Node Comparison
Compare five SmartSolo 3C configurations by sensor specification, weight, storage, endurance and access mode, with links to the English source documents and their test conditions.
These are representative specifications from the cited editions. Confirm the current ordered configuration, accessories and endurance for the actual project; optional storage is not necessarily fitted as standard.
Compare the requirements
On a narrow screen, scroll the table horizontally to see every column.
| Model / source | Frequency specification | Weight¹ | Storage | Published continuous endurance² |
|---|---|---|---|---|
| IGU-16HR 3C 5Hz | 5 Hz natural frequency | 2.4 kg | 64 GB | 30 days at 2 ms, 25 °C |
| IGU-16HR 3C 2Hz | 2 Hz natural frequency | 5.4 kg | 64 GB; expandable to 128 GB | 40 days at 2 ms, 25 °C |
| IGU-16HR 3C AIO 5Hz | 5 Hz natural frequency | 2.8 kg | 64 GB; expandable to 128 GB | 40 days at 2 ms, 25 °C |
| IGU-BD3C-5 | 5 s–150 Hz bandwidth | 2.8 kg | 64 GB; expandable to 128 GB | 30 days at 2 ms, 25 °C |
| IGU-16HR 3C 2Hz ETH | 2 Hz natural frequency | 5.8 kg | 64 GB; expandable to 128 GB | 40 days offline at 2 ms, 25 °C; 7 days with continuous Ethernet transmission |
¹ The cited sheets include the battery and spike for the four non-ETH models; the ETH sheet includes the battery and leveling nuts. Accessories and installed configurations may change transport weight.
² Continuous means 24 hours per day. The ETH sheet lists 7 days for continuous Ethernet transmission separately from offline endurance. Confirm transmission settings and operating conditions for the proposed network.
Shortlist by the measurement requirement
Start with components and the frequency-response requirement. Compare the 2 Hz and 5 Hz geophone models using response and noise data. Include the BD3C-5 when its stated 5 s–150 Hz range matches the experiment. A single frequency number cannot rank these instruments.
Then choose the service workflow
AIO, 2 Hz and BD3C sheets list local Bluetooth QC and USB 3.0 download. The ETH variant lists Ethernet waveform/status access and USB 2.0 download. Select the interface your field team can support, and confirm software, connectors and network infrastructure before procurement.
Request a configuration-specific quotation
Provide the selected model, component count, fitted storage, accessories, temperature range, recording interval and duration. For an Ethernet project, include the power supply, cable distances, backhaul and acceptable data delay. Request current English specifications with the quotation.
English specifications used here
- IGU-16HR 3C — English specification, p. 3 (PDF)
- IGU-16HR 3C 2Hz — English specification, pp. 2–3 (PDF)
- IGU-16HR 3C AIO 5Hz — English specification (2024-11-27), p. 3 (PDF)
- IGU-BD3C-5 — English specification (2025), p. 3 (PDF)
- IGU-16HR 3C 2Hz ETH — English specification (2024-12-05), pp. 2–3 (PDF)
Figures refer to these document editions. Confirm the latest specification and the exact configuration with your quotation.
Explore the instruments

IGU-16HR-3C 5Hz High-Resolution 3-Component Seismic Node
- 3C 5 Hz geophone
- Multiple spike / base options

IGU-16HR-3C 2Hz Low-Frequency 3-Component Seismic Node
- 2 Hz for deep-structure imaging
- High-capacity 6P2S battery

IGU-16HR 3C AIO 5Hz All-in-One 3-Component Seismic Node
- Integrated bucket-style design
- 64 GB onboard storage

IGU-BD3C-5 3-Component Broadband Smart Seismic Node
- 0.2–150 Hz broadband recording
- Up to 30 days continuous recording*

IGU-16HR-3C ETH Ethernet 3-Component Seismic Node
- Ethernet port for online data
- 2 / 5 / 10 Hz options
Plan the application
Documented field examples
These accounts describe their cited projects. They do not prescribe a configuration for a different site.
Continue your comparison
1C vs 3C Seismic Nodes
Choose one component when the survey needs a single measurement axis; choose three components when horizontal motion, polarization or component ratios are part of the analysis.
View comparison →Natural frequency2 Hz vs 5 Hz Geophone Nodes
Use the target signal band and the complete sensor response to compare 2 Hz and 5 Hz nodes. Natural frequency alone does not define usable bandwidth or guarantee greater investigation depth.
View comparison →