2 Hz vs 5 Hz Geophone Nodes
Use the target signal band and the complete sensor response to compare 2 Hz and 5 Hz nodes. Natural frequency alone does not define usable bandwidth or guarantee greater investigation depth.
The values below describe representative IGU-16HR 3C configurations in the linked English specifications. They do not describe every 2 Hz or 5 Hz sensor on the market.
Compare the requirements
On a narrow screen, scroll the table horizontally to see every column.
| Published item | IGU-16HR 3C 2Hz | IGU-16HR 3C 5Hz |
|---|---|---|
| Seismic channels | 3 | 3 |
| Sensor natural frequency | 2 Hz | 5 Hz |
| Weight, including battery and spike | 5.4 kg | 2.4 kg |
| Storage in the cited specification | 64 GB; expandable to 128 GB | 64 GB |
| Continuous operation at 25 °C, 2 ms interval | 40 days | 30 days |
| What still needs confirmation? | Response curve, noise, any extended-response processing, and site coupling. | Response curve, noise, target-band performance, and site coupling. |
Start with the lowest useful signal frequency
If low-frequency observations are central to the project, include the 2 Hz model in a response and noise comparison. If the method uses a higher band, also assess the lighter 5 Hz model against field logistics. Neither label determines the final depth or resolution of an interpreted section.
Do not confuse extended response with a flat native response
The 2 Hz brochure also describes an extended low-frequency response. Before relying on it, request the applicable response file, processing assumptions and noise information. This comparison keeps the 2 Hz natural-frequency value separate from a broadband bandwidth specification.
Compare the complete deployment
For large station counts, carrying weight, battery servicing and download throughput may influence the workable layout. Request the same recording mode and temperature assumptions for all candidates; the published figures are planning references rather than a site-specific endurance guarantee.
English specifications used here
- IGU-16HR 3C 2Hz — English specification, pp. 2–3 (PDF)
- IGU-16HR 3C — English specification, p. 3 (PDF)
Figures refer to these document editions. Confirm the latest specification and the exact configuration with your quotation.
Explore the instruments

IGU-16HR-3C 2Hz Low-Frequency 3-Component Seismic Node
- 2 Hz for deep-structure imaging
- High-capacity 6P2S battery

IGU-16HR-3C 5Hz High-Resolution 3-Component Seismic Node
- 3C 5 Hz geophone
- Multiple spike / base options
Plan the application
Documented field examples
These accounts describe their cited projects. They do not prescribe a configuration for a different site.
Continue your comparison
1C vs 3C Seismic Nodes
Choose one component when the survey needs a single measurement axis; choose three components when horizontal motion, polarization or component ratios are part of the analysis.
View comparison →Sensor responseBroadband vs Geophone Seismic Nodes
Compare a stated broadband response range with the complete response of a geophone node. Both can use a nodal recording workflow; the sensor response and the deployment architecture are separate choices.
View comparison →